This report finds that relying on coal power plant extensions in Australia is high-risk because plant reliability typically drops to an average availability of 66% in the ten years preceding retirement, potentially creating massive energy supply shortfalls.

Key insights

AI-generated

These insights are written by a language model reading the source document. They are not the publisher's words and are not a substitute for the original.

Learn more about AI enrichment
  • Operational coal power stations in the National Electricity Market (NEM) have an average age of 38 years, which is close to the historical average retirement age of 42 years. By 2030, 64% of the remaining coal fleet capacity will be older than this historical average.
  • The reliability of coal plants declines as they age; analysis of 13 closed NEM power stations shows that their average availability in the 10 years before retirement was only 66%.
  • Modelling by Frontier Economics that proposes delaying coal closures assumes coal generation levels that are significantly higher than historical evidence suggests. Correcting for a realistic 66% capacity factor reveals an average annual electricity supply shortfall of 9,300 GWh between 2034 and 2043, equivalent to the consumption of 2 million homes.
  • Filling the projected coal generation gap with gas-fired power would require an average of 67 petajoules (PJ) of additional gas per year from 2034-43, representing a 40% to 76% increase in average past five-year annual gas use for electricity generation.
  • Ageing coal infrastructure increases the risk of catastrophic failures. Historical examples include the 2014 Hazelwood mine fire, boiler pipe explosions at Muja AB, and a catastrophic explosion at Callide C in May 2021.
  • Refurbishing old coal plants is costly and risky. Examples include Muja AB, where refurbishment costs reached $308 million (three times the original budget) and the plant operated at only 20% utilisation before closing in 2017.
  • Private financing for coal plant extensions is increasingly unavailable due to ESG policies. Delta Electricity found that 13 of 15 approached banks were unwilling to provide finance for the Vales Point power station.
  • The risk of energy gaps is exacerbated by the long lead times of nuclear power. Based on an average historical time overrun of 11 years for recent projects in Europe and the US, a potential energy supply gap of 9,600 GWh to 94,500 GWh per year could occur between 2036 and 2051 if nuclear entry is delayed.

Cite the original document

APA
Bowyer, J., & Edis, T. (n.d.). Delaying coal power exits: A risk we can’t afford. Institute for Energy Economics and Financial Analysis. https://ieefa.org/sites/default/files/2025-04/Delaying%20coal%20power%20exits-Apr25.pdf
Chicago
Bowyer, Johanna, and Tristan Edis. Delaying coal power exits: A risk we can’t afford. Institute for Energy Economics and Financial Analysis, n.d. https://ieefa.org/sites/default/files/2025-04/Delaying%20coal%20power%20exits-Apr25.pdf.
Wikipedia
{{cite report |last1=Bowyer |first1=Johanna |last2=Edis |first2=Tristan |title=Delaying coal power exits: A risk we can’t afford |publisher=Institute for Energy Economics and Financial Analysis |url=https://ieefa.org/sites/default/files/2025-04/Delaying%20coal%20power%20exits-Apr25.pdf |access-date=5 November 2026 |via=Climate Insights Directory (document ieefa-001120)}}
BibTeX
@techreport{bowyernddelaying, author = {Bowyer, Johanna and Edis, Tristan}, title = {{Delaying coal power exits: A risk we can’t afford}}, institution = {Institute for Energy Economics and Financial Analysis}, url = {https://ieefa.org/sites/default/files/2025-04/Delaying%20coal%20power%20exits-Apr25.pdf}, urldate = {2026-11-05}, note = {Indexed by Climate Insights Directory, document ieefa-001120} }

Full text

Collected · Record updated