Action Plan Report on Urban Cooling for Can Tho city
Summary
The report establishes a roadmap for sustainable urban cooling in Can Tho, finding that the proposed UCAP scenario could reduce cooling electricity consumption by 45% and GHG emissions by 53% by 2050 compared to a business-as-usual scenario.
Key insights
- Urbanised areas in Can Tho, specifically Ninh Kieu, Binh Thuy, Cai Rang, and O Mon, experience the highest land surface temperatures, with central districts seeing green space coverage as low as 31.6% in 2018 compared to 82.4% in peri-urban and suburban areas.
- On-site measurements from June 2023 showed that the urban neighbourhood of 91B had higher ambient temperatures than the rural ward of Nhon Ai, with a maximum daytime temperature difference of 6°C and a diurnal deviation of around 4°C.
- Simulations using ENVI-Met indicate that urbanisation in the 91B area increases the Physiological Equivalent Temperature (PET) by 2°C compared to its original state; nighttime effects are more severe, with PET values exceeding 54°C in built-up areas versus 32°C in the original landscape.
- Long-term projections (2081-2100) suggest a rise in maximum mean temperature to approximately 36°C, an increase of over 2°C from historical levels, with heatwave duration expected to increase sixfold to between 120 and 280 days.
- Extreme heat is projected to cause significant productivity loss for heavy labourers in Can Tho, peaking in May at 47% in the long-term (2071-2100), with almost all days in a year classified as 'unsafe' for heavy labour.
- Heat-related hospitalisations in Can Tho are estimated to rise by 14% in the long-term, increasing the daily average from 30 per day (2003-2013) to 34.24 per day (2081-2100).
- Building simulations show that exterior environments can account for over 20% of cooling loads, while window systems with low Solar Heat Gain Coefficient (SHGC) and effective external shading can account for 25% to 40% of peak cooling load.
- By 2050, the proposed UCAP scenario is projected to reduce cooling electricity consumption by 45% (787GWh per year), peak cooling load by 36% (426MW), and GHG emissions by 53% (564 thousand tons) compared to the business-as-usual (BAU) scenario.
- The report identifies several barriers to urban cooling in Can Tho, including a lack of awareness among stakeholders, a lack of technical expertise studies to quantify the UHI effect, the absence of a dedicated policy framework, and ambiguous institutional arrangements.
- Recommended nature-based solutions include following WHO guidelines for 9m² of green space per person, ensuring at least 40% of public spaces in hotspot areas are shaded, and using a 70:30:70 ratio for high trees, bushes, and grass in urban green spaces.
Cite the original document
- APA
- Global Green Growth Institute (2025). Action Plan Report on Urban Cooling for Can Tho city. https://gggi.org/wp-content/uploads/2025/10/Final-Report-on-Urban-Cooling-Action-Plan_Can-Tho_ENG.pdf
- Chicago
- Global Green Growth Institute. Action Plan Report on Urban Cooling for Can Tho city. 2025. https://gggi.org/wp-content/uploads/2025/10/Final-Report-on-Urban-Cooling-Action-Plan_Can-Tho_ENG.pdf.
- Wikipedia
- {{cite report |author=Global Green Growth Institute |title=Action Plan Report on Urban Cooling for Can Tho city |date=August 2025 |url=https://gggi.org/wp-content/uploads/2025/10/Final-Report-on-Urban-Cooling-Action-Plan_Can-Tho_ENG.pdf |access-date=5 November 2026 |via=Climate Insights Directory (document gggi-000357)}}
- BibTeX
- @techreport{globalgreengrowthinstitute2025action, author = {{Global Green Growth Institute}}, title = {{Action Plan Report on Urban Cooling for Can Tho city}}, institution = {Global Green Growth Institute}, year = {2025}, month = aug, url = {https://gggi.org/wp-content/uploads/2025/10/Final-Report-on-Urban-Cooling-Action-Plan_Can-Tho_ENG.pdf}, urldate = {2026-11-05}, note = {Indexed by Climate Insights Directory, document gggi-000357} }
Full text
Collected · Record updated