AN ADDITION TO THE FIJI NATIONAL BUILDING CODE SUSTAINABILITY CHAPTER
Summary
The document outlines a comprehensive set of guidelines for the Fiji National Building Code to address climate risks. It focuses on reducing solar heat gain through orientation and insulation, maximizing natural ventilation, and ensuring safe building siting. It emphasizes resilience through storm-resistant glazing, flood mitigation, and redundant essential services. Mitigation strategies include the use of local and recycled materials, energy-efficient cooling and lighting, and solar energy adoption. Finally, it integrates universal design principles to improve accessibility and occupant wellbeing.
Key insights
- To adapt to rising temperatures, buildings should be oriented with longer sides facing North-South to reduce solar heat gain, and windows on East and West facing walls should be avoided unless they are well-shaded.
- The guide recommends specific thermal insulation standards to prevent radiant heat gain, suggesting that roof insulation for all building types should aim for an R-value of 5.68.
- Natural ventilation is mandated for individual dwellings and recommended for others, with specific minimum opening areas required as a percentage of floor area: 20% for bedrooms and living rooms, and 25% for kitchens in dwellings.
- To mitigate storm impacts, all buildings must be designed to withstand updated design wind loads, utilize compact shapes (squares or rectangles where length is less than three times the width), and have pitch roof angles steeper than 22 degrees to minimize uplift.
- Resilience measures for flood-prone areas include using materials that can withstand temporary inundation for up to 72 hours, such as concrete and glazed brick, and elevating sensitive electrical and mechanical equipment.
- For non-residential buildings, particularly those serving as Evacuation Centres, redundant electricity and water supplies are mandatory; backup electricity must cover at least 25% of usual consumption levels.
- Climate mitigation requirements include a mandate that building and renovation projects incorporate at least 15% locally-manufactured materials by total building cost to reduce embodied energy from transportation.
- Energy efficiency mandates for all building classes include the use of high-efficiency LED or fluorescent lighting for at least 90% of fixtures and the installation of thermostats for all air-conditioning systems.
- Water efficiency standards are mandated across all building classes, specifying maximum flow rates of 6L/min for showerheads and 2L/min for faucets in public and private bathrooms.
- The document incorporates Universal Design to ensure accessibility, mandating that non-residential buildings provide clear wayfinding signage, accessible toilets on every floor, and specific minimum dimensions for lobbies and ramps.
Cite the original document
- APA
- Global Green Growth Institute (2022). AN ADDITION TO THE FIJI NATIONAL BUILDING CODE SUSTAINABILITY CHAPTER. https://gggi.org/wp-content/uploads/2022/04/22005_GGGI_SustainabilityChapter_v03_DL_001-high-compressed-1.pdf
- Chicago
- Global Green Growth Institute. AN ADDITION TO THE FIJI NATIONAL BUILDING CODE SUSTAINABILITY CHAPTER. 2022. https://gggi.org/wp-content/uploads/2022/04/22005_GGGI_SustainabilityChapter_v03_DL_001-high-compressed-1.pdf.
- Wikipedia
- {{cite report |author=Global Green Growth Institute |title=AN ADDITION TO THE FIJI NATIONAL BUILDING CODE SUSTAINABILITY CHAPTER |date=2022 |url=https://gggi.org/wp-content/uploads/2022/04/22005_GGGI_SustainabilityChapter_v03_DL_001-high-compressed-1.pdf |access-date=5 November 2026 |via=Climate Insights Directory (document gggi-000164)}}
- BibTeX
- @techreport{globalgreengrowthinstitute2022addition, author = {{Global Green Growth Institute}}, title = {{AN ADDITION TO THE FIJI NATIONAL BUILDING CODE SUSTAINABILITY CHAPTER}}, institution = {Global Green Growth Institute}, year = {2022}, url = {https://gggi.org/wp-content/uploads/2022/04/22005_GGGI_SustainabilityChapter_v03_DL_001-high-compressed-1.pdf}, urldate = {2026-11-05}, note = {Indexed by Climate Insights Directory, document gggi-000164} }