This report assesses the Nyarugenge Pension Plaza in Kigali, finding that while its water efficiency is relatively high, there are significant opportunities to reduce energy consumption and GHG emissions through LED lighting upgrades and improved building envelope management.

Key insights

AI-generated

These insights are written by a language model reading the source document. They are not the publisher's words and are not a substitute for the original.

Learn more about AI enrichment
  • The Nyarugenge Pension Plaza (NPP) has an Energy Performance Index (EPI) of approximately 80 kWh/m2/year, which indicates significant potential for energy reduction when compared to high-efficiency benchmarks (5-star labels) that fall below 40 kWh/m2/year.
  • The building's annual indirect greenhouse gas emissions from grid-supplied electricity are 171.5 tonneCO2e, excluding Scope 1 emissions from diesel generators.
  • The Water Efficiency Index (WEI) for NPP is approximately 0.66 m3/m2/year, which is lower than the median value for office buildings with water-cooled cooling towers in Singapore (1.1 m3/m2/year).
  • The building's architectural orientation along the North-South axis and a high window-to-wall ratio on the western façade lead to excessive heat gain and glare, necessitating the use of internal blinds.
  • Lighting systems are inefficient, utilizing 18W CFLs and T8 fluorescent lamps; replacing these with LED lighting could yield energy cost savings between 37% and 55% for office spaces and 53% for the parking block.
  • The building uses refrigerants R134a, R22, and R-410A; R22 is an ozone-depleting substance being phased out under the Montreal Protocol, and all three have high Global Warming Potential (GWP).
  • Waste management is currently inadequate, with paper, cardboard, and plastic waste being stored unsegregated and likely sent to landfills.
  • There is a significant rainwater harvesting potential of 4,750 cubic meters annually based on the building's 5,000 sq. m. rooftop area and Kigali's annual precipitation.

Cite the original document

APA
Global Green Growth Institute (2020). Rapid Building Performance Assessment of Nyarugenge Pension Plaza Kigali, Rwanda. https://gggi.org/wp-content/uploads/2020/11/Rapid-Building-Performance-Assessment_NPP-October-2020-.pdf
Chicago
Global Green Growth Institute. Rapid Building Performance Assessment of Nyarugenge Pension Plaza Kigali, Rwanda. 2020. https://gggi.org/wp-content/uploads/2020/11/Rapid-Building-Performance-Assessment_NPP-October-2020-.pdf.
Wikipedia
{{cite report |author=Global Green Growth Institute |title=Rapid Building Performance Assessment of Nyarugenge Pension Plaza Kigali, Rwanda |date=October 2020 |url=https://gggi.org/wp-content/uploads/2020/11/Rapid-Building-Performance-Assessment_NPP-October-2020-.pdf |access-date=5 November 2026 |via=Climate Insights Directory (document gggi-000721)}}
BibTeX
@techreport{globalgreengrowthinstitute2020rapid, author = {{Global Green Growth Institute}}, title = {{Rapid Building Performance Assessment of Nyarugenge Pension Plaza Kigali, Rwanda}}, institution = {Global Green Growth Institute}, year = {2020}, month = oct, url = {https://gggi.org/wp-content/uploads/2020/11/Rapid-Building-Performance-Assessment_NPP-October-2020-.pdf}, urldate = {2026-11-05}, note = {Indexed by Climate Insights Directory, document gggi-000721} }

Full text

Collected · Record updated