This guide defines a point-based compliance system for new Category 4 and 5 buildings in Rwanda, requiring a minimum score of 60 out of 190 points and the fulfillment of all mandatory indicators to achieve green building certification.

Key insights

AI-generated

These insights are written by a language model reading the source document. They are not the publisher's words and are not a substitute for the original.

Learn more about AI enrichment
  • To achieve green building minimum compliance, a project must implement all mandatory indicators and score at least 60 points out of a total possible 190 points.
  • The compliance system is mandatory for new Category 4 and 5 buildings, including commercial buildings (excluding warehouses and retail shops), public administrative and institutional buildings (excluding correctional services, police, and fire departments), social, cultural, and assembly buildings, health facilities, and educational buildings (excluding student living areas).
  • The system is organized into five modules: Energy Efficiency (102 points), Water Efficiency (31 points), Environmental Protection (28 points), Indoor Environmental Quality (10 points), and Innovation and Other Green Features (19 points).
  • Mandatory energy efficiency requirements include artificial lighting efficiency and the installation of solar hot water systems for premises with hot water requirements exceeding 100 litres per day.
  • Water efficiency mandates include rainwater harvesting systems that capture 100% of roof run-off, the use of efficient plumbing fixtures, and the treatment of 100% of on-site generated wastewater to Rwanda Standards Board (RSB) discharge standards.
  • Environmental protection requirements mandate the use of refrigerants with zero Ozone Depletion Potential (ODP) for all air-conditioning systems.
  • Indoor Environmental Quality mandates include minimum outdoor fresh air supply for air-conditioned spaces, thermal comfort (indoor temperature between 24°C to 26°C and relative humidity less than 65%), and adherence to noise level tolerance limits.
  • All publicly accessible buildings must be universally accessible, requiring features such as non-slippery ramps with handrails, Braille and audio assistance in lifts, and restrooms designed for differently abled people.
  • The implementation plan includes the digitization of the system by integrating requirements into the Building Permit Management Information System (Bpmis) and training for One Stop Centers and construction professionals.

Cite the original document

APA
Global Green Growth Institute (2019). RWANDA GREEN BUILDING MINIMUM COMPLIANCE SYSTEM. https://gggi.org/wp-content/uploads/2019/07/Annex-3-Rwanda-Green-Building-Minimum-Compliance-System-REVISED.pdf
Chicago
Global Green Growth Institute. RWANDA GREEN BUILDING MINIMUM COMPLIANCE SYSTEM. 2019. https://gggi.org/wp-content/uploads/2019/07/Annex-3-Rwanda-Green-Building-Minimum-Compliance-System-REVISED.pdf.
Wikipedia
{{cite report |author=Global Green Growth Institute |title=RWANDA GREEN BUILDING MINIMUM COMPLIANCE SYSTEM |date=16 April 2019 |url=https://gggi.org/wp-content/uploads/2019/07/Annex-3-Rwanda-Green-Building-Minimum-Compliance-System-REVISED.pdf |access-date=5 November 2026 |via=Climate Insights Directory (document gggi-000217)}}
BibTeX
@techreport{globalgreengrowthinstitute2019rwanda, author = {{Global Green Growth Institute}}, title = {{RWANDA GREEN BUILDING MINIMUM COMPLIANCE SYSTEM}}, institution = {Global Green Growth Institute}, year = {2019}, month = apr, url = {https://gggi.org/wp-content/uploads/2019/07/Annex-3-Rwanda-Green-Building-Minimum-Compliance-System-REVISED.pdf}, urldate = {2026-11-05}, note = {Indexed by Climate Insights Directory, document gggi-000217} }

Full text

Collected · Record updated