Whole building assessment for energy efficiency and zero direct emissions heat in multi-owner and mixed-use buildings
Summary
The report concludes that current UK assessment methods like SAP and SBEM are unsuitable for retrofit design in multi-owner buildings because they focus on regulatory compliance and cannot be aggregated into a single whole-building calculation.
Key insights
- Current assessment methods in the UK, specifically SAP and SBEM, are unsuitable for retrofit design because they are intended for comparison and regulatory compliance rather than absolute calculations of building performance.
- A major limitation for multi-owner and mixed-use buildings is that SAP (used for flats) and SBEM (used for non-domestic and communal spaces) outputs cannot currently be directly compared or aggregated into a single whole-building calculation.
- Option 1, an assumption-based approach updating RdSAP, is low-cost but cannot adequately consider retrofit risks, potentially leading to defects such as damp or mould, and cannot recommend connection to communal or district heating.
- Option 2 proposes using PAS 2035 with full SAP or PHPP modelling to provide a holistic retrofit assessment that mitigates unintended consequences, though it faces a limited supply chain of qualified Retrofit Assessors and Coordinators.
- Option 3 suggests a best-practice approach based on international examples, featuring risk-based scalable data collection and detailed renovation roadmaps, but it would have the highest development costs as it does not build on existing Scottish methods.
- International examples from Denmark, France, and Germany show that multiple assessment approaches can co-exist, with some serving regulatory compliance (EPCs) and others serving long-term retrofit design (Building Renovation Roadmaps).
- Effective whole building assessments for retrofit should not be solely desk-based; they require site visits and, depending on complexity, in-situ testing such as thermography, moisture analysis, and U-value monitoring.
- The report identifies that the Scottish context differs from reviewed international examples due to a lack of formal management structures in multi-owner buildings, a lower prevalence of communal heating, and the practice of assessing only individual flats.
Cite the original document
- APA
- Berner, A., Burns, F., Lancaster, M., & Lochhead, E. (2023). Whole building assessment for energy efficiency and zero direct emissions heat in multi-owner and mixed-use buildings. ClimateXChange. https://www.climatexchange.org.uk/wp-content/uploads/2023/10/cxc-whole-building-assessment-for-energy-efficiency-and-zero-direct-emissions-heat-in-multi-owner-and-mixed-use-buildings-september-2023.pdf
- Chicago
- Berner, Agnes, Freya Burns, Megan Lancaster, and Euan Lochhead. Whole building assessment for energy efficiency and zero direct emissions heat in multi-owner and mixed-use buildings. ClimateXChange, 2023. https://www.climatexchange.org.uk/wp-content/uploads/2023/10/cxc-whole-building-assessment-for-energy-efficiency-and-zero-direct-emissions-heat-in-multi-owner-and-mixed-use-buildings-september-2023.pdf.
- Wikipedia
- {{cite report |last1=Berner |first1=Agnes |last2=Burns |first2=Freya |last3=Lancaster |first3=Megan |last4=Lochhead |first4=Euan |title=Whole building assessment for energy efficiency and zero direct emissions heat in multi-owner and mixed-use buildings |publisher=ClimateXChange |date=March 2023 |url=https://www.climatexchange.org.uk/wp-content/uploads/2023/10/cxc-whole-building-assessment-for-energy-efficiency-and-zero-direct-emissions-heat-in-multi-owner-and-mixed-use-buildings-september-2023.pdf |access-date=5 November 2026 |via=Climate Insights Directory (document climex-000384)}}
- BibTeX
- @techreport{berner2023whole, author = {Berner, Agnes and Burns, Freya and Lancaster, Megan and Lochhead, Euan}, title = {{Whole building assessment for energy efficiency and zero direct emissions heat in multi-owner and mixed-use buildings}}, institution = {ClimateXChange}, year = {2023}, month = mar, url = {https://www.climatexchange.org.uk/wp-content/uploads/2023/10/cxc-whole-building-assessment-for-energy-efficiency-and-zero-direct-emissions-heat-in-multi-owner-and-mixed-use-buildings-september-2023.pdf}, urldate = {2026-11-05}, note = {Indexed by Climate Insights Directory, document climex-000384} }
Full text
Collected · Record updated