Reductions in maximum flow temperatures in Scottish domestic heating

Report an error

Summary

AI-generated

This summary is written by a language model reading the source document. It is not the publisher's words and is not a substitute for the original.

Learn more about AI enrichment

The research finds that while most Scottish homes are currently unsuitable for flow temperatures of 55°C or below during winter peaks, up to 76% could become suitable with higher-cost retrofits.

Key insights

AI-generated

These insights are written by a language model reading the source document. They are not the publisher's words and are not a substitute for the original.

Learn more about AI enrichment
  • Most of the Scottish housing stock is currently unsuitable for reducing flow temperatures to 55°C or below on a winter peak day.
  • Under a higher cost retrofit scenario, 76% of Scottish homes would become suitable for a flow temperature of 55°C on a winter peak day.
  • Approximately 30% of the overall housing stock is unsuitable for a flow temperature below 75°C, and 20% require a flow temperature above 75°C.
  • Reducing flow temperatures can lead to significant fuel bill savings, ranging from £151m to £501m in stringent external temperature test cases.
  • Estimated greenhouse gas emission savings from flow temperature reduction range from 6.17 to 10.18 MtCO2 equivalent per year, depending on the retrofit scenario and external temperature cases.
  • Upgrading radiators is identified as a key retrofit measure; reducing radiator uptake decreases the suitability of the stock at every flow temperature tested in winter peak cases.
  • Post-2002 dwellings and flats are generally the most suitable for lower flow temperatures and are easier to retrofit.
  • Pre-1919 houses are particularly difficult to transition, as they are currently unsuitable for 55°C flow temperatures due to high heat loss and undersized heating systems.
  • A flow temperature of 55°C is considered a feasible target as it balances the efficiency of condensing boilers with the optimal operating range of heat pumps (30-55°C).

Cite the original document

APA
Martin, M., Foster, S., Dias, J., & Benjamin, S. (2025). Reductions in maximum flow temperatures in Scottish domestic heating. ClimateXChange. https://www.climatexchange.org.uk/publications/reductions-in-maximum-flow-temperatures-in-scottish-domestic-heating/
Chicago
Martin, M., S. Foster, J. Dias, and S. Benjamin. Reductions in maximum flow temperatures in Scottish domestic heating. ClimateXChange, 2025. https://www.climatexchange.org.uk/publications/reductions-in-maximum-flow-temperatures-in-scottish-domestic-heating/.
Wikipedia
{{cite report |last1=Martin |first1=M. |last2=Foster |first2=S. |last3=Dias |first3=J. |last4=Benjamin |first4=S. |title=Reductions in maximum flow temperatures in Scottish domestic heating |publisher=ClimateXChange |date=3 April 2025 |url=https://www.climatexchange.org.uk/publications/reductions-in-maximum-flow-temperatures-in-scottish-domestic-heating/ |access-date=5 November 2026 |via=Climate Insights Directory (document climex-000107)}}
BibTeX
@techreport{martin2025reductions, author = {Martin, M. and Foster, S. and Dias, J. and Benjamin, S.}, title = {{Reductions in maximum flow temperatures in Scottish domestic heating}}, institution = {ClimateXChange}, year = {2025}, month = apr, url = {https://www.climatexchange.org.uk/publications/reductions-in-maximum-flow-temperatures-in-scottish-domestic-heating/}, urldate = {2026-11-05}, note = {Indexed by Climate Insights Directory, document climex-000107} }

Full text

Collected · Record updated