The IEEFA finds that the Elmer Smith Station generates excess power that is sold at a loss, meaning retail customers are subsidizing wholesale sales, and recommends retiring Unit 1 by 2019 and Unit 2 by 2022.
Key insights
- Owensboro Municipal Utility (OMU) generates more power than it needs because retail annual peak loads and energy sales have remained relatively flat since 2004, resulting in an average surplus capacity of as much as 295 MW from the 405 MW net capacity of the Elmer Smith Station (ESS).
- Retail ratepayers in Owensboro are subsidizing the sale of excess power to wholesale customers because wholesale revenues cover only 44.6% of the Elmer Smith Station's fixed costs.
- The IEEFA recommends shutting down ESS Unit 1 in 2019 and Unit 2 by 2022, noting that electric rates would be lower as early as 2017 if the decision to retire Unit 2 in 2022 were made.
- Continued operation of ESS Unit 2 through 2030 would lead to dramatic increases in electric rates, with projected increases of approximately 20 percent between 2016 and 2018 and more than 80 percent between 2016 and 2025.
- OMU has rejected solar and wind resources as not being the lowest cost options without providing supporting economic analysis or discussing the economics of energy efficiency.
- The IEEFA advises OMU to avoid equity investments in new or existing natural gas combined cycle gas turbine (CCGT) plants and instead use the wholesale market or short- to mid-length Power Purchase Agreements (PPAs) to maintain flexibility.
- Environmental compliance costs for ESS include $25 million for Coal Combustion Residuals in FY 2018, $12 million for Effluent Limitation Guidelines in FY 2021, and $7 million already invested in Mercury and Air Toxics in FY 2015/2016.
Cite the original document
- APA
- Institute for Energy Economics and Financial Analysis (n.d.). omu-memorandum-8ca9b53a52f31fab.pdf. https://ieefa.org/sites/default/files/resources/OMU-Memorandum.pdf
- Chicago
- Institute for Energy Economics and Financial Analysis. omu-memorandum-8ca9b53a52f31fab.pdf. n.d. https://ieefa.org/sites/default/files/resources/OMU-Memorandum.pdf.
- Wikipedia
- {{cite report |author=Institute for Energy Economics and Financial Analysis |title=omu-memorandum-8ca9b53a52f31fab.pdf |url=https://ieefa.org/sites/default/files/resources/OMU-Memorandum.pdf |access-date=5 November 2026 |via=Climate Insights Directory (document ieefa-001770)}}
- BibTeX
- @techreport{instituteforenergyeconomicsandfinancialanalysisndomumemorandum8ca9b53a52f31fabpdf, author = {{Institute for Energy Economics and Financial Analysis}}, title = {{omu-memorandum-8ca9b53a52f31fab.pdf}}, institution = {Institute for Energy Economics and Financial Analysis}, url = {https://ieefa.org/sites/default/files/resources/OMU-Memorandum.pdf}, urldate = {2026-11-05}, note = {Indexed by Climate Insights Directory, document ieefa-001770} }
Full text
Collected · Record updated