Gorgon Carbon Capture and Storage: The Sting in the Tail
Summary
The Gorgon CCS project underperformed its carbon capture targets by approximately 50% during its first five years of operation. This failure demonstrates the inherent technical risks of CCS and leaves Australian taxpayers liable for the project's costs after its closure.
Key insights
- The Gorgon CCS project failed to meet its carbon injection targets by approximately 50% during its first five years of operation, having injected only 4.9MT of CO2 by July 2021 against an inferred target of about 10.1MT.
- The CCS facility experienced significant delays and technical failures, with CO2 injection not starting until August 2019, three and a half years after the LNG plant began operations in March 2016.
- Technical issues contributing to underperformance included leaking corroded valves, excess water in pipelines, and sand blocking the water reinjection well, which compromised the pressure management system.
- To compensate for a shortfall of 5.23 million tonnes of CO2, Chevron has agreed to purchase greenhouse gas offsets, with estimated costs ranging between US$100 million and US$184 million.
- The Gorgon project's long-term liability is transferred to the Western Australian state government and taxpayers after its 40-45 year operational life and subsequent 15-year closure period.
- The report argues that Gorgon's failures are typical of the broader technical risks associated with CCS technology, noting that most global CCS projects face unique engineering challenges and cost overruns.
Cite the original document
- APA
- Robertson, B., & Mousavian, M. (2022). Gorgon Carbon Capture and Storage: The Sting in the Tail. Institute for Energy Economics and Financial Analysis. https://ieefa.org/wp-content/uploads/2022/03/Gorgon-Carbon-Capture-and-Storage_The-Sting-in-the-Tail_April-2022.pdf
- Chicago
- Robertson, Bruce, and Milad Mousavian. Gorgon Carbon Capture and Storage: The Sting in the Tail. Institute for Energy Economics and Financial Analysis, 2022. https://ieefa.org/wp-content/uploads/2022/03/Gorgon-Carbon-Capture-and-Storage_The-Sting-in-the-Tail_April-2022.pdf.
- Wikipedia
- {{cite report |last1=Robertson |first1=Bruce |last2=Mousavian |first2=Milad |title=Gorgon Carbon Capture and Storage: The Sting in the Tail |publisher=Institute for Energy Economics and Financial Analysis |date=April 2022 |url=https://ieefa.org/wp-content/uploads/2022/03/Gorgon-Carbon-Capture-and-Storage_The-Sting-in-the-Tail_April-2022.pdf |access-date=5 November 2026 |via=Climate Insights Directory (document ieefa-001280)}}
- BibTeX
- @techreport{robertson2022gorgon, author = {Robertson, Bruce and Mousavian, Milad}, title = {{Gorgon Carbon Capture and Storage: The Sting in the Tail}}, institution = {Institute for Energy Economics and Financial Analysis}, year = {2022}, month = apr, url = {https://ieefa.org/wp-content/uploads/2022/03/Gorgon-Carbon-Capture-and-Storage_The-Sting-in-the-Tail_April-2022.pdf}, urldate = {2026-11-05}, note = {Indexed by Climate Insights Directory, document ieefa-001280} }
Full text
Collected · Record updated