Deep-Dive Assessment of 250 Buildings in Cambodia

Report an error

Summary

AI-generated

This summary is written by a language model reading the source document. It is not the publisher's words and is not a substitute for the original.

Learn more about AI enrichment

The assessment of 250 buildings in Cambodia reveals that most structures rely on outdated, inefficient equipment, but implementing targeted retrofits like inverter ACs and LED lighting can provide significant energy savings with payback periods typically under four years.

Key insights

AI-generated

These insights are written by a language model reading the source document. They are not the publisher's words and are not a substitute for the original.

Learn more about AI enrichment
  • Retail supermarkets exhibit the highest life-cycle carbon footprint in Cambodia, while pagodas have the lowest.
  • The residential sector, specifically serviced apartments and apartments/condominiums, shows the highest electricity consumption levels, with serviced apartments peaking at approximately 7.5 million kWh annually.
  • The building sector in Cambodia heavily relies on outdated technology, including fixed-speed split AC units (many using R22 refrigerant), induction ceiling fans, and T5/T8 fluorescent tube lights.
  • Twelve energy conservation measures (ECMs) were identified, with most showing a payback period of less than four years, except for rooftop solar PV systems which have an estimated payback of eight years.
  • Cambodia's Energy Performance Index (EPI) shows strength in educational buildings (64.6 kWh/m²/yr) but significant opportunities for improvement in the hospitality (171 kWh/m²/yr), retail (205.5 kWh/m²/yr), and commercial (131.6 kWh/m²/yr) sectors.
  • Embodied carbon is dominated by reinforced cement concrete (RCC) structures, which were used in 228 of the 250 assessed buildings, with the largest shares of emissions coming from foundations (13%), slabs (12%), columns (7%), and beams (6%).
  • Rooftop solar PV deployment is hindered by the lack of net metering and the introduction of compensation tariffs for grid-connected systems.
  • High window-to-wall ratios (WWR) and clear glazing on south- and west-facing façades without shading lead to excessive solar heat gain and increased cooling loads.

Cite the original document

APA
Global Green Growth Institute (2026). Deep-Dive Assessment of 250 Buildings in Cambodia. https://gggi.org/wp-content/uploads/2026/06/Deep-Dive-Assessment-Report-Cambodia.pdf
Chicago
Global Green Growth Institute. Deep-Dive Assessment of 250 Buildings in Cambodia. 2026. https://gggi.org/wp-content/uploads/2026/06/Deep-Dive-Assessment-Report-Cambodia.pdf.
Wikipedia
{{cite report |author=Global Green Growth Institute |title=Deep-Dive Assessment of 250 Buildings in Cambodia |date=June 2026 |url=https://gggi.org/wp-content/uploads/2026/06/Deep-Dive-Assessment-Report-Cambodia.pdf |access-date=5 November 2026 |via=Climate Insights Directory (document gggi-000293)}}
BibTeX
@techreport{globalgreengrowthinstitute2026deepdive, author = {{Global Green Growth Institute}}, title = {{Deep-Dive Assessment of 250 Buildings in Cambodia}}, institution = {Global Green Growth Institute}, year = {2026}, month = jun, url = {https://gggi.org/wp-content/uploads/2026/06/Deep-Dive-Assessment-Report-Cambodia.pdf}, urldate = {2026-11-05}, note = {Indexed by Climate Insights Directory, document gggi-000293} }

Full text

Collected · Record updated