صحيفة حقائق الفرص التي أبلغ عنها الشرآاء رقم ١٠٩
Summary
The document outlines a method for reducing methane emissions during compressor shutdowns by redirecting purge gas to a fuel gas system. This practice, reported by the Phillips Enron Gas Pipeline Group, can recover approximately 12,000 cubic feet of gas per shutdown event. For a station with six compressors experiencing 42 shutdowns annually, the estimated savings are 500,000 cubic feet of methane per year. Capital costs for necessary piping and valves are estimated between $900 and $1,600 per compressor, with a projected payback period of less than three years based on a gas price of $3 per thousand cubic feet.
Cite the original document
- APA
- Clean Air Task Force (2004). صحيفة حقائق الفرص التي أبلغ عنها الشرآاء رقم ١٠٩. https://cdn.catf.us/wp-content/uploads/2025/12/03060416/AR_Lower-Purge-Pressure-for-Shutdown.pdf
- Chicago
- Clean Air Task Force. صحيفة حقائق الفرص التي أبلغ عنها الشرآاء رقم ١٠٩. 2004. https://cdn.catf.us/wp-content/uploads/2025/12/03060416/AR_Lower-Purge-Pressure-for-Shutdown.pdf.
- Wikipedia
- {{cite report |author=Clean Air Task Force |title=صحيفة حقائق الفرص التي أبلغ عنها الشرآاء رقم ١٠٩ |date=September 2004 |url=https://cdn.catf.us/wp-content/uploads/2025/12/03060416/AR_Lower-Purge-Pressure-for-Shutdown.pdf |access-date=23 October 2026 |via=Climate Insights Directory}}
- BibTeX
- @techreport{cleanairtaskforce2004, author = {{Clean Air Task Force}}, title = {{صحيفة حقائق الفرص التي أبلغ عنها الشرآاء رقم ١٠٩}}, institution = {Clean Air Task Force}, year = {2004}, month = sep, url = {https://cdn.catf.us/wp-content/uploads/2025/12/03060416/AR_Lower-Purge-Pressure-for-Shutdown.pdf}, urldate = {2026-10-23}, note = {Indexed by Climate Insights Directory} }
Full text
Collected · Record updated