{"query_echo":{"q":"","filters":{"analysis_type":["walkthrough audit"]},"warnings":[{"code":"facet_value_not_in_vocabulary","message":"Value 'walkthrough audit' for facet 'analysis_type' is not in the controlled vocabulary."}]},"total":{"value":2,"relation":"eq"},"page":1,"page_size":20,"self":"https://climateinsightsdirectory.org/api/v1/search?analysis_type=walkthrough+audit","stability":"beta","ai_marking":{"digital_source_type":{"uri":"http://cv.iptc.org/newscodes/digitalsourcetype/trainedAlgorithmicMedia","name":"Created using Generative AI"},"notice":"Summary and key insights are generated using artificial intelligence."},"results":[{"id":"gggi-000218","url":"https://climateinsightsdirectory.org/document/gggi-000218","title":"Rapid Building Performance Assessment of Administrative Office Complex, Kigali, Rwanda","publisher":{"name":"Global Green Growth Institute","organization":"global-green-growth-institute"},"document_type":"report","language":"en","date_published":"2021-03","source_url":"https://gggi.org/wp-content/uploads/2021/06/AOC-Report_low-res_Final.pdf","generator":"Climate Insights Directory","generated_fields":["summary","key_insights","climate_tags","geography_discussed","analysis_type"],"summary":{"text":"The assessment of the Administrative Office Complex in Kigali finds that while the building has a relatively low Energy Performance Index of 36 kWh/m2/year, there are significant opportunities to reduce GHG emissions and operational costs through LED lighting upgrades and restored rainwater harvesting.","ai_generated":true,"unit":"gggi-000218#summary","date_modified":"2026-11-05"},"key_insights":[{"text":"The Administrative Office Complex (AOC) has an Energy Performance Index (EPI) of approximately 36 kWh/m2/year and a Water Efficiency Index (WEI) of approximately 0.47 m3/m2/year, both of which are considered low when compared to benchmarks in India and Singapore.","ai_generated":true,"unit":"gggi-000218#insight-1","date_modified":"2026-11-05"},{"text":"The building's orientation along the North-West and South-East axis is suboptimal for its location in Kigali, leading to excessive heat gain, particularly on the western façade, which is further exacerbated by a high Window to Wall Ratio (WWR) in the central wing.","ai_generated":true,"unit":"gggi-000218#insight-2","date_modified":"2026-11-05"},{"text":"Approximately 70% of the indoor lighting consists of non-LED fixtures, specifically 18W Fluorescent T8 Tube lights in office spaces, which presents a significant opportunity for energy savings through replacement.","ai_generated":true,"unit":"gggi-000218#insight-3","date_modified":"2026-11-05"},{"text":"The building's air-conditioning system uses R-410A refrigerant, which has a high Global Warming Potential (GWP) of 2088 and should be phased out in accordance with the Kigali amendment to the Montreal Protocol.","ai_generated":true,"unit":"gggi-000218#insight-4","date_modified":"2026-11-05"},{"text":"The rainwater harvesting system, designed to hold approximately 360 cubic meters of water, is currently non-functional because the pump room was submerged during heavy rains in January 2020, damaging the pumping equipment.","ai_generated":true,"unit":"gggi-000218#insight-5","date_modified":"2026-11-05"},{"text":"The wastewater treatment system is inadequate because the grey water tank was constructed as a non-permeable RCC tank rather than a soak pit, causing it to fill quickly and requiring frequent emptying.","ai_generated":true,"unit":"gggi-000218#insight-6","date_modified":"2026-11-05"},{"text":"Annual indirect GHG emissions from grid-supplied electricity for the AOC are estimated at 170.5 tCO2e, based on consumption data from October 2019 to September 2020.","ai_generated":true,"unit":"gggi-000218#insight-7","date_modified":"2026-11-05"}],"climate_tags":["energy efficiency","water efficiency","waste management","green building","greenhouse gas emissions","rainwater harvesting","wastewater treatment","refrigerant","photovoltaics"],"geography_discussed":["India","Singapore"],"frame_perspective":[],"analysis_type":["case study","walkthrough audit","benchmarking"]},{"id":"gggi-000721","url":"https://climateinsightsdirectory.org/document/gggi-000721","title":"Rapid Building Performance Assessment of Nyarugenge Pension Plaza Kigali, Rwanda","publisher":{"name":"Global Green Growth Institute","organization":"global-green-growth-institute"},"document_type":"report","language":"en","date_published":"2020-10","source_url":"https://gggi.org/wp-content/uploads/2020/11/Rapid-Building-Performance-Assessment_NPP-October-2020-.pdf","generator":"Climate Insights Directory","generated_fields":["summary","key_insights","climate_tags","geography_discussed","analysis_type"],"summary":{"text":"This report assesses the Nyarugenge Pension Plaza in Kigali, finding that while its water efficiency is relatively high, there are significant opportunities to reduce energy consumption and GHG emissions through LED lighting upgrades and improved building envelope management.","ai_generated":true,"unit":"gggi-000721#summary","date_modified":"2026-11-05"},"key_insights":[{"text":"The Nyarugenge Pension Plaza (NPP) has an Energy Performance Index (EPI) of approximately 80 kWh/m2/year, which indicates significant potential for energy reduction when compared to high-efficiency benchmarks (5-star labels) that fall below 40 kWh/m2/year.","ai_generated":true,"unit":"gggi-000721#insight-1","date_modified":"2026-11-05"},{"text":"The building's annual indirect greenhouse gas emissions from grid-supplied electricity are 171.5 tonneCO2e, excluding Scope 1 emissions from diesel generators.","ai_generated":true,"unit":"gggi-000721#insight-2","date_modified":"2026-11-05"},{"text":"The Water Efficiency Index (WEI) for NPP is approximately 0.66 m3/m2/year, which is lower than the median value for office buildings with water-cooled cooling towers in Singapore (1.1 m3/m2/year).","ai_generated":true,"unit":"gggi-000721#insight-3","date_modified":"2026-11-05"},{"text":"The building's architectural orientation along the North-South axis and a high window-to-wall ratio on the western façade lead to excessive heat gain and glare, necessitating the use of internal blinds.","ai_generated":true,"unit":"gggi-000721#insight-4","date_modified":"2026-11-05"},{"text":"Lighting systems are inefficient, utilizing 18W CFLs and T8 fluorescent lamps; replacing these with LED lighting could yield energy cost savings between 37% and 55% for office spaces and 53% for the parking block.","ai_generated":true,"unit":"gggi-000721#insight-5","date_modified":"2026-11-05"},{"text":"The building uses refrigerants R134a, R22, and R-410A; R22 is an ozone-depleting substance being phased out under the Montreal Protocol, and all three have high Global Warming Potential (GWP).","ai_generated":true,"unit":"gggi-000721#insight-6","date_modified":"2026-11-05"},{"text":"Waste management is currently inadequate, with paper, cardboard, and plastic waste being stored unsegregated and likely sent to landfills.","ai_generated":true,"unit":"gggi-000721#insight-7","date_modified":"2026-11-05"},{"text":"There is a significant rainwater harvesting potential of 4,750 cubic meters annually based on the building's 5,000 sq. m. rooftop area and Kigali's annual precipitation.","ai_generated":true,"unit":"gggi-000721#insight-8","date_modified":"2026-11-05"}],"climate_tags":["energy efficiency","water efficiency","waste management","green building","greenhouse gas emissions","rainwater harvesting","refrigerant","photovoltaics","building envelope"],"geography_discussed":["India","Singapore"],"frame_perspective":[],"analysis_type":["policy analysis","case study","walkthrough audit"]}]}